SPC for Cap Torque Control Limits on the Line

By Lim Xu, Export Manager

SPC for cap torque means plotting application or removal torque in time order and drawing control limits from the line's own data. The usual tool is an X-bar and R chart with 3-sigma limits, and the constants it needs are published in ASTM E2587, Table 1.

Control limits and specification limits do different jobs

Specification limits come from the pack. They say what removal or application torque the closure has to deliver, and they are usually agreed with the closure supplier or the customer.

Control limits come from the process. They describe where the capper is centred and how much it normally varies, so they can sit well inside the specification or, on a poorly running line, partly outside it.

Our guide on how to set a cap torque specification covers the specification window. Use that window to accept or reject product, and use the control chart to see whether the capper is still behaving the way it did when you qualified it.

Collect subgroups the line can explain

ASTM E2587 defines a rational subgroup as one chosen to keep variation within the subgroup small and variation between subgroups large. On a capping line that usually means a few consecutive bottles from the same head, taken close together in time.

Four or five bottles per subgroup is a common choice. Chart application torque and removal torque separately, and do not mix fresh bottles with bottles that have been stored, because torque decay makes them a different series.

Record the time, the head, the cap lot and the tester setup with each subgroup. Our digital cap torque tester is used for this kind of closure check, and our note on how to interpret torque test data explains the mean, standard deviation and coefficient of variation behind each point.

Questions about a model or a test? Email Amy Zhao, Export Manager, at [email protected].

The X-bar and R chart formulas

For each subgroup of n bottles, work out the average X̄ and the range R, which is the highest reading minus the lowest. Across k subgroups, the grand average X̿ is the mean of the X̄ values and R̄ is the mean of the ranges.

  • X-bar chart: centre line X̿, upper limit X̿ + A2 × R̄, lower limit X̿ − A2 × R̄
  • R chart: centre line R̄, upper limit D4 × R̄, lower limit D3 × R̄

The 3-sigma idea is built into the constants. R̄ divided by d2 estimates the process standard deviation, an average of n readings varies by that amount divided by the square root of n, and A2 equals 3 divided by d2 times the square root of n.

The values below are taken from ASTM E2587, Table 1, Control Chart Factors. The same table continues to n = 10 and also gives the A3, B3 and B4 factors for an X-bar and s chart.

Subgroup size nA2D3D4d2
21.88003.2671.128
31.02302.5751.693
40.72902.2822.059
50.57702.1142.326
60.48302.0042.534

A worked example with round numbers

Say 25 subgroups of five bottles give X̿ = 20.0 and R̄ = 2.0, in whatever torque unit your tester reports. These figures are only there to show the arithmetic. They are not a torque target for any closure.

With n = 5, A2 is 0.577, so the upper limit is 20.0 + 0.577 × 2.0 = 21.15 and the lower limit is 18.85. The R chart runs from 0 to 2.114 × 2.0 = 4.23, and the estimated standard deviation is 2.0 / 2.326 = 0.86.

Now compare those limits with the specification. If the specification window is much wider than 18.85 to 21.15, the capper has room to drift before product is at risk. If it is narrower, the chart is telling you the process cannot hold the specification even when nothing has gone wrong.

Reading the chart and recalculating limits

Read the R chart first. The X-bar limits are built from R̄, so if the ranges are out of control the X-bar limits cannot be trusted yet.

A point beyond either 3-sigma limit is the basic signal. The NIST/SEMATECH e-Handbook of Statistical Methods, section 6.3.2, lists the Western Electric supplementary rules: two of three successive points beyond 2 sigma on one side, four of five beyond 1 sigma, and eight in a row on one side of the centre line.

Extra rules catch small shifts sooner but raise more false alarms, so pick a rule set and write it on the chart. When a signal appears, look at the capper head, the clutch setting, the cap lot, the liner, the neck finish and the tester fixture.

Treat the first limits as trial limits. Remove subgroups with a cause you have found and fixed, then recalculate once. After a known change, such as a new cap lot, a new liner or a repaired head, start a new chart rather than stretching the old limits.

Frequently asked questions

Can I use the specification limits as control limits?

No. Specification limits describe what the pack must meet, while control limits describe how the process normally behaves. Using the specification as control limits hides drift until product is already near the edge.

Why is the lower limit on my R chart zero?

For subgroups of six or fewer, D3 in ASTM E2587 Table 1 is 0, so the lower range limit is 0. A range chart only gains a lower limit from n = 7 upward.

Should a multi-head capper go on one chart?

Not as mixed subgroups. Bottles from different heads in one subgroup inflate the range and widen the limits, so a single bad head can hide. Chart each head, or keep each subgroup to one head and label it.

Talk to our factory team

We sell direct from our factory, so you work directly with our factory team. Questions about a model or a test? Email Amy Zhao, Export Manager, at [email protected].

Related articles

About Author
Lim Xu
Export Manager, KHT Instruments

Ready to Upgrade Your Quality Control?

Act Now

Get the factory-direct precision you need. Contact us for a quote and technical consultation.

View our privacy policy.

© 2026 KHT NLY-20A Torque Tester | All rights reserved.