Torque Testing for Retort and HPP Packaging Closures
By Lim Xu, Export Manager
Torque testing for retort and HPP packaging closures is a before-and-after check: the same cap and finish, measured with the same method, so you can see whether heat or high-pressure processing has moved application or removal torque outside a usable window.
Why closures need a check after the process
Retort applies heat, often with steam or water, to a sealed pack. High-pressure processing (HPP) applies a high hydrostatic pressure, usually with the pack already closed. Both can change the liner, the plastic cap, the neck, or the product at the thread.
The result may be a cap that is harder to open, easier to open, or unchanged. This article does not quote a typical shift, because that amount depends on the pack, the process and the time of measurement, and should be measured on the pack you are qualifying.
A closure that met the window on the filling line can sit outside it after the retort or the HPP cycle, or after later storage. A first-day, unprocessed result is not a life-of-pack result.
What to measure, and when
Plan at least three looks, and write the time of each on the sheet: immediately after capping, after the process has finished and the pack has returned to a stated handling temperature, and after an agreed period of storage.
Application torque belongs to the capper, and is usually measured as the pack is closed. Removal torque is the value most people care about after retort or HPP, because that is what the user, or a later inspection, will feel. Our article on cap application torque versus removal torque covers that pair.
If the pack has an induction liner or a foil seal, say whether the cap is being removed from an intact seal or after the seal has been broken. Those results are not the same series.
ASTM D2063 is a method for torque retention of continuous-thread closures under controlled conditions. It may be a starting point if your cap is a continuous-thread closure. Confirm the method against the official text and against your specification; a retort or HPP pack may also name a different method.
Want to see a cap torque check on retort or HPP closures like yours? Tell us what you need to test. We test a similar material sample and send you the video, so you do not need to ship a sample. If you prefer to send your own, we accept that too.
Keeping the comparison fair
Use the same lot of caps and bottles, the same liner, and the same tester setup for the before and after measurements. Change only the process and the time, or you will not know which factor moved the result.
Let packs return to the agreed test temperature before you measure removal torque. A cap taken straight from a hot retort basket and a cap that has cooled on the bench are not comparable.
Record the process in enough detail that another person can repeat the comparison: retort or HPP, the cycle identity you are allowed to write, and the time from the end of the process to the test. Do not invent a typical cycle.
Our digital cap torque tester is used for closure torque work of this kind. How a given retort jar, bottle or HPP bottle should be clamped is something to confirm with us. This article does not state torque values or instrument ranges.
Using the results in a specification
The after-process removal torque, and the value after storage, are the figures that belong in a use window, next to leak or seal checks. Our guide on how to set a cap torque specification describes that wider process.
If after-process torque is too high to open, or too low to stay closed, do not only turn the capper up or down. Look at the liner, the resin, the process and the neck finish with the supplier. A tighter cap on the line will not always survive heat or pressure in a more openable way.
When the window is set, re-check it after a change of cap, liner or cycle. A result from the first trial is not a standing setting.
Frequently asked questions
Can I skip the before-process measurement?
You can, but you will not know whether a high or low result came from the capper or from the process. A before-and-after pair is the point of this check.
Is a retort result valid for an HPP pack of the same cap?
No. The processes are different. Measure the process you will actually run.
How long should I wait after the process before I test?
Use the interval in your specification, or an interval you can defend and then keep. If you have not yet agreed one, please confirm it with us rather than borrowing a time from another pack.
Get a test video for your closures
Tell us what you need to test, such as the material, the size and the test method. We test a similar material sample on the instrument you are looking at and send you the video, so you do not need to ship a sample. If you prefer to send your own, we accept that too.