Torque Testing for Twist-Off Lids on Glass Jars

By Lim Xu, Export Manager

Twist-off lids on glass jars of low-acid food are held on mainly by vacuum, not by torque alone. FDA guidance calls removal torque a valuable quality check but does not recommend it as the control for cap application. Use it next to pull-up and security checks, which look at how the lid was applied.

How twist-off lids hold on a glass jar

FDA's inspection guide for low-acid canned food manufacturers describes the vacuum closures used on glass jars. The lug cap is the main type. It has a steel shell with four, six or eight metal lugs, depending on its diameter, and normally a flowed-in plastisol gasket.

The capper sweeps the headspace with steam and twists the cap so the lugs seat under the threads on the glass finish. The top of the finish contacts the gasket. Both the lugs and the vacuum hold the cap in place, and the guide names vacuum as the more important of the two.

The press-on twist-off (PT) cap has no lugs and is widely used on baby food. It is heated, pushed straight down onto the finish, and the glass threads form impressions in the gasket on its skirt. Vacuum holds it in place, with some help from those impressions once the cap cools.

A third type, the plastisol-lined continuous thread cap, screws on like a normal threaded cap. Security can be measured on it, but pull-up cannot.

What removal torque tells you on a vacuum jar

Removal torque is the force needed to take the cap off, usually measured with a torque meter. The FDA guide treats it as a valuable quality control check. It does not recommend it as the control for cap application.

FDA's guide does not say why. Our reading is that vacuum also holds a lug or PT cap on, so removal torque reflects more than how far the capper turned it. FDA's Bacteriological Analytical Manual notes that a stripped cap may have vacuum but has no security value. In our reading, that is why lug caps are judged with pull-up and security checks, and torque should be paired with both.

Our NLY-20A digital cap torque tester measures both removal and application torque. Record removal torque on the same jars you open for the security test, so the two sets of results can be compared over time.

Questions about a model or a test? Email Amy Zhao, Export Manager, at [email protected].

Pull-up and security checks for lug caps

Pull-up is a non-destructive check of where the lug sits on the glass thread. Find the vertical neck ring seam on the finish, then measure to the leading edge of the nearest lug in sixteenths of an inch. The guide warns that this seam does not always line up with the two vertical seams on the glass finish.

A lug to the right of the seam is positive and means the cap was applied properly. A negative position can point to over-application and a stripped cap. A lug usually sits about a quarter inch to the right, but readings from zero to half an inch can still go with good security.

Security measures the lug tension of the applied cap, and the guide calls it the most reliable check of lug cap application. Ranges come from the closure manufacturer. The test is destructive and runs in four steps.

  1. Mark a vertical line on the cap and a matching line on the jar.
  2. Turn the cap counterclockwise until the vacuum breaks.
  3. Reapply the cap until it is finger tight.
  4. Measure the gap between the two lines in sixteenths of an inch.

A cap line to the right of the jar line is positive security, and a line to the left is negative. A high positive value can mean under-application, and a negative value can mean over-application that needs action right away. Pull-up does not replace security, but it becomes useful once you know how the two relate on your line.

Building a closure check routine for jars

The guide describes the required pace for low-acid foods in glass. A qualified person checks at least one jar from each capper head for visible defects at intervals of no more than 30 minutes. The check is repeated after a jam, an adjustment or a long shutdown.

Destructive checks are done by a trained closure technician at intervals of no more than 4 hours of continuous capper operation. Before filling starts, a cold-water vacuum check confirms a steam flow capper can form a vacuum, and the result is recorded.

Keep removal torque in the destructive set, alongside vacuum, the gasket impression and security. Our guide on how to set a cap torque specification covers continuous thread closures. It shows how to choose an application torque window and the removal torque you expect after storage.

Lid defects to look for when a jar fails

Start with what you can see. A cocked cap happens when a lug fails to seat under the glass thread, and it usually leaves the cap tilted. On lug and PT caps, the guide limits the gap between the bottom of the cap and the transfer bead to 3/32 inch.

A crushed lug has been forced down over the glass thread and looks bent inward, but it may not tilt the cap. A stripped cap was applied with so much torque that the lugs passed over the glass threads. FDA's Bacteriological Analytical Manual notes that a stripped cap may still have vacuum but has no security value.

After removal, the plastisol gasket should show a continuous, even impression from the glass finish. A cut-thru, where the finish has pushed through the gasket to the metal, can leak and calls for immediate action.

Frequently asked questions

Should security readings be the same before and after retorting?

No. The FDA guide says security can be measured at the capper and after processing and cooling, but the range should be lower after processing. Heat and pressure make the gasket compound sink, so compare readings taken at the same stage.

How much vacuum should a jar have after capping?

The vacuum range is recommended by the container manufacturer. For the cold-water check on a steam-flow capper, the FDA guide says it typically should be 22 inches or more. For a PT cap, it asks for at least 3 inches of vacuum after capping to avoid loose caps. The guide gives these figures in inches and does not name the unit.

Talk to our factory team

We sell direct from our factory, so you work directly with our factory team. Questions about a model or a test? Email Amy Zhao, Export Manager, at [email protected].

Related articles

About Author
Lim Xu
Export Manager, KHT Instruments

Ready to Upgrade Your Quality Control?

Act Now

Get the factory-direct precision you need. Contact us for a quote and technical consultation.

View our privacy policy.

© 2026 KHT NLY-20A Torque Tester | All rights reserved.